- FC1862 controller with 4 line card, max. 1008 points.

- Fulfill Chinese Standard of GB4717-2005 and GB16806-2006.

- Multi-language operation menu with windows style, easy and fast operation.

- Shortcut key (right key) for popping out operation items of device/event.

- Large memory space for up to 10000 history records, first in first out order, all events can be recorded during the operation period.

- LCD backlight Auto-off mode. When no operation or event to display within preset time, LCD backlight will be automatically turn off. When there are events / operations, LCD will light up automatically to display events and/or interlocking devices.

- 2 channels of programmable input/output (output: 40mA@24VDC, it can be programmed as general alarm output or general trouble output; input: dry contact). 

- 1 channel of NAC for audible and visible device (0.5A@24VDC).

- 8 channels of interlocking function (output: 40mA @ 24VDC ) for automatic control and manual operations of control equipments.

- Efficient group programming according to different using.

- A FC186x controller can connect up to 2016 points by adding line card.

- Network bus (FC18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 controllers can be networked.

- FRT bus (FR18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 floor repeater displays can be networked.

- Detection bus (FD18-BUS), 2-wire polarity-free, the max. distance for line resistance is 4000m, the max. distance for line capacitance is 5000m. (the twist wiring capacity is 1.0 to 1.5 mm2)

- Three user levels for different operation authority. Each user level is accessed by a pre-defined and changeable password.

- Convenient pluggable terminals with clear marks for field wiring.

- Auto-mapping function to support on commissioning task.

- Detection algorithm can be adjusted by controller according to environment, to provide high reliability of alarm and reduce false alarm.

- Programming can be done either directly on controller or through computer.

- “Sticker Method” easy for commissioning on site.

Thông số ky thuật

Model FC-1862/'FC1861-A2
Max. No. of line cards8
Max. No. of devices2016
LCD screen320×240 pixels, backlit
No. of programmable input/ output on mainboard2
No. of NAC (0.5mA @24VDC)1
Max. history records10000
Max. distance between controllers within FC18-BUS1000 m
Max. No. of controllers networked within FC18-BUS16
Max. distance between a controller and a FRT/Mimic driver within FR18-BUS1000 m
Max. No of FRT/Mimic driver connected with a controller32
Auto-mapping functionAvailable(only for detection line and field device)
Battery (not included)Depends on local regulation
Communication interfaceSpecial converter module
Input voltage220 V@3A, 110 V@6A
220 V/50Hz ,110 V/60Hz
Power supply capacity10 A@24 VDC
Dimension (In: mm)1000×600×200
Weight (without battery)34 Kg
Power fuse 220V:3.0 A , 110V:6.0A
Battery fuse10.0 A (DC)
Operating temperature0 ~ +40℃
Storage temperature-10 ~ +50 ℃
Humidity≤95%(40±2 ℃)
Environment requirementindoor