Trung tâm báo động HONEYWELL VISTA-20P

Trung tâm báo động HONEYWELL VISTA-20P

  • MS 000010928
  • HONEYWELL
Giá : Liên hệ

Trung tâm báo động HONEYWELL VISTA-20P

Trung tâm báo động HONEYWELL VISTA-20P

- Trung tâm báo VISTA-20P có thể mở rộng lên đến 40 Zones có dây hoặc không dây.

- Tích hợp đa chức năng hỗ trợ người dùng.

Tính năng

- IP alarm reporting and uploading/downloading capability for Internet and Intranet use via iGSMV4G, 7845i-ENT, GSMV4G or GSMX4G.

- Supports four graphic touchscreen keypads.

- Wireless keys can be programmed without using zones.

- Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)

   + 40 hardwire expansion zones

   + 40 wireless expansion zones

- Two low current on-board trigger outputs

- 100 Event Log viewable at system keypads with time/date stamp

- 48 system user codes assignable to either partition

- Expandable to 48 total zones when used with hardwired and/or wireless expansion modules

- Two independent partitions plus a common partition

   – Global Arming from any system keypad

   – Go to function to view or operate one partition from the other

   – Separate partition account numbers

- 16 output devices: Relays (Model 4204 Relay Modules, or 4229 Expansion Module)

- Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes

- Supports four-wire and up to 16 two-wire smokes: Works with Sentrol CleanMe™ maintenance signal

- Multiple actions on output devices depending on system state

- Turns lights off when system arms

   + Turns the same light on when system disarms

   + Flashes same lights when system is in alarm

- Built-in phone line cut monitor with programmable delay and annunciation options

   + Display on system keypads

   + Trigger local sounders

   + Trigger system bell

Thông số kỹ thuật

ModelVISTA-20P
System Capacities
Maximum Zone Capacity 48
Std. Hardwired Zones (with zone doubling) 8 (15)
Maximum ECP Hardwire Expansion Zones40
Maximum Wireless Expansion Zones40
Wireless Keys (do not use zones)16 
Partitions2 ''true''
User Codes48
Event Log100 
Maximum Number Two-Wire Smokes16
Maximum Number of Schedules32
False Alarm Prevention Features
Exit Error Logic
Exit Delay Reset 
Exit Delay Countdown 
Cross Zoning 
Alarm Verification – Fire 
Swinger Shutdown
Unvacated Auto-Stay
Alarm Cancel Verification
System Configuration
Interactive Phone Support
Real Time Clock
Temporal Bell
Bell Supervision
Telephone Line Monitor
On-board Triggers2
Relays Supported16
Additional Features
Cross Partitioning (go to)
“Night” Arming
RF Supervision by Transmitter
Common Lobby Logic
Configurable Zone Type
“Battery Saver”
Keyswitch Arming
Convenience Features
Single Button Arming 
Quick Exit 
Keypad Macros 
Viewable Event Log at Keypad 
Pager Capability 4
Auto Arm/Disarm 
Graphic Keypad Support 4
Internet and GSM Communication Support 
LTE Communication Support
Note: ✓ Supported Feature

- Bảo hành: 12 tháng.  